Adonis Samson - 6KVA UPS
Adonis Samson is a 6KVA UPS designed for heavy workloads and Data centers. Samson provides up to 4800Watts of power in a true online ups flow. True Online battery load prevents spikes, outages, and drop offs caused by power to battery switching.
Packages for in-stock items are generally dispatched within 7 days after receipt of payment and are shipped via NZPOST with tracking and drop-off without signature. Whichever shipment choice you make, we will provide you with a link to track your package
Please do not immediately return your goods if you find them to be damaged or you are claiming a warranty repair. Please contact us first for an RMA authorization before returning your item.
Adonis Samson is a 6KVA UPS designed for heavy workloads and Data centers. Samson provides up to 4800Watts of power in a true online ups flow. True Online battery load prevents spikes, outages, and drop offs caused by power to battery switching.
Adonis Samson incorporates double-conversion inverter technology eliminating all mains power disturbances. A rectifier converts the alternating current from the utility power to direct current which is used to charge the batteries and power the inverter that then generates a true online sinusoidal AC voltage into the inverter to power the load.
Adonis Samson provides perfect protection specifically for computer equipment, Communication systems, and sensitive computerized instruments.
With a easy read LCD display, input and output voltage and frequency can be viewed alongside load level and batter charge level.
Model |
Samson C6K |
|
Rated output capacity |
6kVA/4800W |
|
Rated voltage |
220Vac |
|
Rated frequency |
50Hz |
|
Input voltage range |
(120~275)VAC +/- 5% |
|
Input frequency range |
45-55 +/- 0.5Hz |
|
Bypass voltage |
80VAC |
|
Battery input |
Battery voltage |
12VDC/*7AH*16 |
Battery section number |
16 |
|
Backup time (Approximate values only. Results will vary based on load average) |
1/4 Load ~ 50 mins Half load ~ 10 to 20 mins full load ~ 5 mins |
|
Boot input maximum impact current |
< Rated current 150% |
|
Battery charge time |
5 hours to 90% |
|
AC output |
Output mode |
Single phase |
Output voltage |
220Vac +/- 3%(inverter output) |
|
Output frequency |
50/60Hz +/- 5Hz(Normal AC input) 50/60 Hz +/- 1% |
|
Dynamic voltage transients |
< 5% |
|
Dynamic transient recovery time |
< 60ms |
|
Wave |
Sine wave THD < 3% (linear load) Sine wave THD <8% (nonlinear load) |
|
Output power factor |
0.8 |
|
Overload capacity |
130% of Load Recovery point is 90% load |
|
Peak coefficient of output current |
3:1 |
|
Reverse to bypass conversion time |
< 4ms |
|
Communication and monitoring function |
RS232 |
|
Weight (net weight)/(gross weight) |
58KG / 61KG |
|
Size (UPS) |
248*500*616 (mm) |
|
Dimension (packing) (W*D*H, mm) |
320*650*750 (mm) |
|
Certification |
CE EN 62040-1:2008 |
|
Warranty - Return to base |
3 Years |
UPS install should be undertaken by qualified electricians. Load capacity draw is equal to input capacity. Unit will run on standard input loading to a 10A fuse provided that output load is no more than 2200W. Purchasers must make sure that the fuse loading and cabling are sufficient to run the output load. If running a full 4800W load, installer must make sure that proper electrical wiring is installed to cabling sufficient to handle 40A connected to a 32A fuse.